Ecoer FAQs

Honeywell T-Series Thermostat Setu
How to set up a Honeywell T-Series Thermostat to the Ecoer unit. *  The Thermostat is shipped with a setup of Cooling Only operation we must configure the ...
Tue, 9 Jun, 2020 at 1:16 PM
Unit Running in Heating at Startup (Ecoer Unit)
Units that run in heating during startup is usually caused by incorrect setup of the electronic menu on the thermostat. 1) Make sure the Tstat is wired ...
Thu, 11 Jun, 2020 at 6:45 PM
AHRI Certificate Numbers (ECOER)
Wed, 24 Jun, 2020 at 12:03 PM
What is the updated SEG3 AC STATE on the Outdoor MCB?
Fri, 26 Jun, 2020 at 2:56 PM
What are the prices for the IoT Monitoring?
Fri, 26 Jun, 2020 at 2:56 PM
The cutting point for the Hi-Pressure Switch to go off on the ODU?
520 Psi
Fri, 26 Jun, 2020 at 2:57 PM
What does the condenser do when the unit is on Dry Mode?
Condenser restricts the flow of refrigerant to the evaporator to be able to lower the saturated evap temp to about 28 degrees, so that when the air touches ...
Fri, 26 Jun, 2020 at 2:59 PM
Why can't I run a Furnace & Heat Pump together?
When a Furnace & Heat Pump Run at the same time the Freon that is deigned to sit inside the copper tubing will begin to evaporate and make it's way ...
Fri, 26 Jun, 2020 at 3:28 PM
What kind of fuse & Amp Rating is used in the two Ecoer Air Handlers?
G Series Fuse Amp Rating - 3.15 Amps  E Series Fuse Amp Rating - 4 Amps  
Mon, 29 Jun, 2020 at 10:51 AM
Even though the unit is not calling for anything, some amp draw is coming out of the Compressor, why is that?
 The reason for this is because the Internal Heater in the compressor is active to keep oil warm for lubrication purposes. Plus, the active main control boa...
Mon, 29 Jun, 2020 at 10:55 AM